TC1200 REFERENCE MANUAL
28
3
READING PARAMETERS PARAMETERS
Description Parameter Value
Illumination Mode Disabled SPIL 00
Triggered 01
Enabled 02
Operating Modes On Line SNRM 00
Serial On Line 01
Automatic 02
Automatic (Object Sense) 03
Test 04
Automatic Threshold From 2 to 255 scans without a code SNAT g
Phase Off Event Trigger Stop SNTO 00
Timeout 01
Trigger Stop-Timeout 02
Timeout From 40 to 5100 ms SNET h
Serial Start Any string of characters (max 20) between 00-FE STON i
Serial Stop Any string of characters (max 20) between 00-FE STOF i
LED Indication On Decode BPIN 00
After Transmission 01
Label Programming Mode Disabled FAPM 00
Enabled 01
Exposure Mode Continuous SPST 00
Strobed 01
Reading Conditions Auto SNCO 00
Standard 01
High Resolution (Far) 02
Difficult 03
Blurred (Near) 04
g = Hex value from 02 to FF representing the number of scans without a code
h = Hex value from
02 to FF representing the decimal number (x20 ms)
i = Hex value from
00 to FE representing the ASCII character
DATA FORMAT
Description Parameter Value
Data Transmission On Decode LFTX 01
After Phase Off 00
Code Verifier Mode Disabled LFCV 00
Transmit Wrong String 01
Transmit Wrong Code 02
Match String Any string of characters (max 20) between 00-FE COVS k
Wrong Code String Any string of characters (max 20) between 00-FE WCVS k
Case Conversion Disable LFCA 00
Upper Case 01
Lower Case 02
Global Prefix (Header) Any string of characters (max 20) between 00-FE LFPR k
Global Suffix (Terminator) Any string of characters (max 20) between 00-FE LFSU k
No Read String Any string of characters (max 20) between 00-FE NORS k
Character Conversion An 8-character string between 00-FF LFCH m
Transmit AIM IDs Disable AIEN 00
Enable 01
Transmit Custom Label IDs Disable IDCO 00
Prefix 01
Suffix 02
GS1-128 AIM ID Disable U8AI 00
Enable 01
k = Hex value from 00 to FE representing the ASCII character
m = 8 Hex values from
00 to FF representing the 8 ASCII characters (FF = no replacement or ignore)