Miscellaneous
7
OPTICON Universal menu book
U127
7. MISCELLANEOUS
7.1. Diagnostics
The options in this part are primarily intended
for diagnostic purposes. The following options
are available:
Transmit software version:
The software version is transmitted.
Transmit ROM checksum:
The software calculated checksum over the
internal program is transmitted.
Transmit settings:
The reader settings are transmitted as a string
of hexadecimal numbers.
Transmit ASCII printable string:
The printable ASCII characters Hex 20 upto
Hex 7F are transmitted.
Transmit ASCII control string:
The non printable ASCII control characters Hex
00 upto Hex 1F are transmitted.
SET
_ZZ_
Transmit software version
Z1
_Z1_
Transmit ROM checksum
ZY
_ZY_
Transmit settings
Z3
_Z3_
Transmit ASCII printable
string
ZA
_ZA_
Transmit ASCII control
string
YV
_YV_
END
_ZZ_
Vista de pagina 133
1 2 ... 129 130 131 132 133 134 135 136 137 138 139 ... 150 151